Secure the chimney support band using two 2 1 4 x 2 and two 2 1 4 x 1 2 bolts.
Selkirk roof brace kit installation.
Remember that safety comes first.
Braces adjust from 4 to 6.
Place the chimney support band around the chimney at a minimum height of 1 2 2 3 or greater if possible the distance that th e chimney extends above the roof.
Instructions chase top shroud.
Braces should be at 45 degree angle to the chimney or at any convenient angle when at minimum length 4 6 total.
Adjustable wall band 0015163.
Roof brace kit t rbk.
Bolt brace tubes to band and attach angle brackets to roof with lag screws into structure bending brace and tabs as necessary.
Diameters 5 through 14.
Install flashing and storm collar in usual manner.
Heavy duty roof brace kit 3002537.
Roof brace kit requirements.
Selkirk 6t rbk roof brace kit 6 product information technical details.
Mh special mobile home joist shield and cathedral ceiling adapter.
Secure the angle brackets to the roof structure using two 2 1 4 x 2 lag screws per brackets see figure 7.
Extended wall support 2002410 gs general installation instructions.
Custom chase tops and shrouds.
The roof brace kit should be used at a midpoint on the chimney.
Anchor plate with damper.
Universal roof brace kit urbk jurgk 1 read instructions carefully before starting the project.
And carry the listing mark illustrated here.
Though it was not hard to install there are pipes that need to be slid into other pipes and doing that on the roof with.
Roof support rafter radiation shield roof flashing universal roof guy kit masonry adapter kit adapter plate maintenance and cleaning of chimney replacement parts list chart 1 offset chimney installation chart 2 chimney height above the roof chart 3 connector pipe clearances cathedral support installation record product registration.
Apply a thin layer of caulking under the angle bracket before securing in place as well as over the lag screw heads.
Chimney height 6 to 10 feet above the roof always requires a roof brace kit.
Our chimney systems are designed for installation by a qualified person in accordance with local building codes.
Ensure the fasteners are into rafters or framing and not just roof sheathing.
Fits selkrik ultra temp class a pipe i d.
Build chimney to desired height and locate external guy band at 1 2 h above the roof.